Fully-automated quality assurance in multi-center studies using MRI phantom measurements [Dataset] (doi:10.11588/data/RR5BMF)

View:

Part 1: Document Description
Part 2: Study Description
Part 5: Other Study-Related Materials
Entire Codebook

(external link)

Document Description

Citation

Title:

Fully-automated quality assurance in multi-center studies using MRI phantom measurements [Dataset]

Identification Number:

doi:10.11588/data/RR5BMF

Distributor:

heiDATA

Date of Distribution:

2019-02-05

Version:

1

Bibliographic Citation:

Davids, M.; Zöllner, F.; Ruttorf, M.; Nees, F.; Flor, H.; Schumann, G.; Schad, L.; the Imagen Consortium, 2019, "Fully-automated quality assurance in multi-center studies using MRI phantom measurements [Dataset]", https://doi.org/10.11588/data/RR5BMF, heiDATA, V1

Study Description

Citation

Title:

Fully-automated quality assurance in multi-center studies using MRI phantom measurements [Dataset]

Identification Number:

doi:10.11588/data/RR5BMF

Authoring Entity:

Davids, M. (Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University)

Zöllner, F. (Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University)

Ruttorf, M. (Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University)

Nees, F. (Department of Cognitive and Clinical Neuroscience, Central Institute of Mental Health, Medical Faculty Mannheim, Heidelberg University)

Flor, H. (Department of Cognitive and Clinical Neuroscience, Central Institute of Mental Health, Medical Faculty Mannheim, Heidelberg University)

Schumann, G. (MRC Social, Genetic and Developmental Psychiatry Centre, London, UK and Institute of Psychiatry, King’s College London, UK)

Schad, L. (Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University)

the Imagen Consortium (Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University)

Software used in Production:

Matlab

Grant Number:

LSHMCT- 2007-037286

Distributor:

heiDATA

Access Authority:

Zöllner, F.

Holdings Information:

https://doi.org/10.11588/data/RR5BMF

Study Scope

Keywords:

Medicine, Health and Life Sciences, MRI, Automated quality assurance, Phantom measurement, Multicenter study

Abstract:

43 measurements acquired in eight different sites within the <a href="https://imagen-europe.com/">IMAGEN-project</a>, comprising the following 3 T scanner types: Siemens Verio and TimTrio; General Electric Signa Excite, and Signa HDx; Philips Achieva. <p> Additionally one phantom data set was aquired on a 3 T Siemens Skyra resulting in 44 measurements.

Methodology and Processing

Sources Statement

Data Access

Other Study Description Materials

Related Materials

<a href="http://ikrsrv1.medma.uni-heidelberg.de/redmine/projects/ummacrqe">Matlab scripts</a>

Related Publications

Citation

Title:

M. Davids, F. Zöllner, M. Ruttorf, F. Nees, H. Flor, G. Schumann and L. Schad and the IMAGEN Consortium. Fully-automated quality assurance in multi-center studies using MRI phantom measurements. Magn Reson Imaging, 2014, 32, pp.771-780

Identification Number:

10.1016/j.mri.2014.01.017

Bibliographic Citation:

M. Davids, F. Zöllner, M. Ruttorf, F. Nees, H. Flor, G. Schumann and L. Schad and the IMAGEN Consortium. Fully-automated quality assurance in multi-center studies using MRI phantom measurements. Magn Reson Imaging, 2014, 32, pp.771-780

Other Study-Related Materials

Label:

IMAGen_Phantom.zip

Notes: